Verified Pharmaceutical Machinery Manufacturers in India
Pharmaceutical machinery is the set of presses, capsule fillers, granulators, dryers, coaters and blenders that formulation plants use to make tablets and capsules. diipl matches buyers with verified Indian makers and arranges a direct meeting.
Also called: Pharma Machinery, Pharmaceutical Equipment, Tablet Press Machine, Tablet Compression Machine, Capsule Filling Machine.
in India
from abroad
this machine
What is a commercial pharmaceutical machinery?
Pharmaceutical machinery is the group of processing machines that turn powders into tablets and capsules. Powders are blended first. Many products are then granulated, either wet with a liquid binder in a high shear granulator or a fluid bed, or dry by compaction between rolls, and wet granules are dried. A rotary tablet press compresses the granules between punches and dies. A capsule filler doses powder, pellets or small tablets into capsule shells. A coater tumbles finished tablets while it sprays a coating liquid onto them, then dries the coat. Parts that touch the product must not react with it and must be easy to clean between batches. Formulation plants and contract units run these machines in batches.
This page covers commercial and industrial machines that make tablets and capsules; packing machines and home-use or hobby models are not covered.
How diipl verifies pharmaceutical machinery manufacturers
diipl checks every pharmaceutical machinery manufacturer before a buyer meets them. Every seller is GSTIN verified and capacity audited. IEC and the certifications your product and market need (ISO, CE, REACH, BIS) are confirmed before any meeting; Certificate of Origin and EIC inspection are arranged per shipment where required.
For pharmaceutical machinery, the capacity audit also covers:
- A trial run of the press, granulator, dryer or coater at rated load on the factory floor, using a sample of your own material or a stand-in, with output, tablet weight variation and temperatures recorded
- How product-contact parts are made: material certificates, weld and polish finish, and where seals and lubricants sit in relation to the product
- Whether turrets, die tables, bowls, drums and vessels are machined and welded in house, and which gauges check punch, die and turret dimensions
- Dust-control design on the machine itself: closed charging and discharge, sealed lids, and the filter housings and extraction points on dryers and coaters
- A document pack ready for audit, with drawings, factory test protocols and calibration certificates, plus a stock of spare punches, dies and wear parts
We match your requirement to a manufacturer that has passed these checks and arrange a direct meeting.
Types of pharmaceutical machinery we cover
Indian pharmaceutical machinery manufacturers on the diipl bench build these commercial and industrial types.
| Type | Typical buyers |
|---|---|
| Rotary tablet press | Tablet plants, contract manufacturing units and supplement makers running regular batches |
| Automatic capsule filling machine | Capsule plants, contract manufacturing units and nutraceutical makers |
| Rapid mixer granulator | Plants that make tablets or capsule fills from wet granules |
| Fluid bed dryer and processor | Plants that dry granules and pellets after wet granulation |
| Tablet coating pan and drum coater | Tablet plants that coat their products |
| Container blender | Plants that blend powders and granules before compression or filling |
Rotary tablet press
A rotary tablet press carries a ring of punch and die stations on a turning turret, so each turn presses many tablets. One maker's medium presses list 30 to 43 stations, tooling types D, B and BB, main and pre-compression force up to 100 kN, and rated output of 18,000 to 206,400 tablets an hour, depending on tooling size, shape and material. Choose it for steady, high-volume tablet batches.
Automatic capsule filling machine
An automatic capsule filler doses powders, pellets or small tablets into capsule shells and can check the closing force. One maker lists three models: up to 3,600 capsules an hour, 3,000 to 43,500, and up to 156,600. Powder is dosed by a tamping pin with slide gate or by a vacuum dosator, and a checkweigher can weigh every capsule. Choose it when volumes are steady and fill weight must be tracked closely.
Rapid mixer granulator
A rapid mixer granulator, a high shear type, first mixes the dry powders with an impeller, then takes in a sprayed binder liquid so the impeller forms wet granules while a chopper breaks up oversized lumps. One maker's pilot and production models span container volumes from 25 to 1,800 litres, with filling levels between 20 and 80 percent. Choose it when tablets are made by wet granulation.
Fluid bed dryer and processor
A fluid bed dryer keeps wet granules moving in a stream of process air so that they dry. The same type of machine can also granulate and coat in one product container. One maker's main production series lists batches from 25 kg to 1,600 kg, with a filter that cleans element by element, and says its systems are pressure-shock resistant. Choose it to dry granules after wet granulation.
Tablet coating pan and drum coater
A coater tumbles tablets in a rotating pan or drum while spray guns apply the coating liquid, and the coat is then dried. One maker's production coaters use a horizontally rotating, perforated drum with baffles and spray guns on an arm, list batch capacity from 175 to 1,000 litres and verified filling levels between 10 and 100 percent, and clean automatically. Choose it for coated tablets.
Container blender
A container blender blends dry powders and granules inside a container, and the blending is gentle on the product and gives a homogeneous mix. One maker lists drum and container blenders for filling volumes up to 3,000 litres, tilting container blenders for straightforward blending, and a series with a lifting function that can charge production equipment. Choose it to blend before compression or capsule filling.
What to specify when buying a pharmaceutical machinery
A clear pharmaceutical machinery specification gets you comparable offers and a faster meeting. Share these points with diipl and we match them to the right manufacturer.
| What to specify | Why it matters |
|---|---|
| Tablet press: stations, tooling type and rated output | Output grows with stations and turret speed. One maker lists small presses with 20 to 30 stations rated at 12,000 to 144,000 tablets an hour. Output depends on tooling and material, so ask for output proven on your own granules. |
| Compression force, tablet size and die fill depth | One maker's medium press lists main and pre-compression force up to 100 kN, tablet diameter from 13 to 25 mm by tooling, and die fill depth up to 20 mm. Match these to your largest, hardest and thickest tablet. |
| Weight control, tablet rejection and force feeding | Ask whether compaction force control sets tablet weight automatically, whether one bad tablet can be rejected at top speed, and how the feeder fills the dies. One maker lists all three, with zero-clearance force feeding. |
| Product-contact parts, seals and lubricants | Revised Schedule M says contact parts must not be reactive, additive or absorptive enough to affect quality, and cleaning and lubrication materials must not directly touch the product. Ask for material certificates, weld and polish finish, oil leak points. |
| Dust control and enclosure | Revised Schedule M asks for effective dust control on each tablet compressing machine, and for dust extractors or a dedicated area on mixing, sifting and blending equipment that is not closed. Ask what enclosure and extraction connection the machine offers. |
| Capsule filler: output, dosing method and fill material | One maker lists models from up to 3,600 capsules an hour to up to 156,600, with tamping pin or vacuum dosator dosing. Confirm the capsule sizes covered, how fill weight is checked, and whether your fill suits the dosing. |
| Granulator: container volume, filling level and endpoint | One maker's pilot and production models span 25 to 1,800 litres of container volume and run at filling levels between 20 and 80 percent. The endpoint is read from time and current, with torque as an option. |
| Fluid bed: batch size, process air and filters | One maker's main production series lists batches from 25 kg to 1,600 kg. Key parameters are air flow, spray rate, spray pressure, and inlet air humidity and temperature. Ask about filter type and filter cleaning. |
| Explosion protection of granulators and dryers | Dust or solvent vapour can create an explosive atmosphere. One maker offers either pressure-shock resistant execution or inertization, to suit your safety concept. Say what you process and ask which design is fitted. |
| Coater: drum, batch capacity, spray and cleaning | A perforated drum with baffles tumbles tablets under spray guns on an arm. One maker lists production capacity of 175 to 1,000 litres, filling levels between 10 and 100 percent, and fully automatic cleaning. |
| Blender: container volume and charging | One maker lists drum and container blenders for filling volumes up to 3,000 litres, and says charging is done with a lifting trolley. Ask the working fill level for your bulk density and how containers are cleaned between products. |
| Changeover, cleaning and access | Ask how long a product changeover takes and how turrets, bowls, drums and filter bags come out for cleaning. One maker states complete product changeovers in less than one hour and turret removal in as little as fifteen minutes. |
| Qualification documents and factory test | Revised Schedule M asks for design, installation and operational qualification of equipment. Ask for design documents against your specification, a factory test protocol, installation and operation protocols, current drawings and calibration records. |
| Electrical supply, machine weight and footprint | State plant voltage, frequency and phases. One maker's medium press lists 220, 380, 415 and 480 V three phase at 50 or 60 Hz, an 11 kW main motor, 3,920 kg net weight and a 158 by 143 cm footprint. |
Who buys pharmaceutical machinery
Pharmaceutical Machinery is bought by these commercial and industrial buyers, in India and abroad.
Buyers in India
- Formulation plants that make tablets and capsules
- Contract manufacturing units and loan licence holders running batches for other brands
- Nutraceutical and dietary supplement makers
- Makers of active ingredients that granulate or coat powders
- Pilot plants and development units of formulation companies scaling up new products
Buyers abroad
- Generic formulation plants in Africa
- Tablet and capsule plants in South-East Asia
- Formulation and supplement makers in the Middle East and GCC
- Contract manufacturers and plant expansions in Latin America
- Formulation plants in South Asia
HSN code and ITC-HS code for pharmaceutical machinery
The code for pharmaceutical machinery depends on which machine it is, because tablet presses, capsule fillers, mixers and granulators, and dryers each fall under a different heading, and no official text settles the line for tablet coating pans and drum coaters. Choose the line that matches your machine:
- 84798970 (machinery for the manufacture of chemical and pharmaceuticals goods) when the machine presses powder into tablets between punches and dies and the tablets are pharmaceutical goods.
- 84223000 (machinery for filling, closing, sealing or labelling bottles, cans, boxes, bags or other containers machinery for capsuling bottles, jars, tubes and similar containers, machinery for aerating beverages) when the machine fills capsule shells with powder, granules or pellets and closes them.
- 84798200 (mixing, kneading, crushing, grinding, screening, sifting, homogenising, emulsifying or stirring machines) when the machine mixes, blends or granulates powders, such as a rapid mixer granulator, a container blender, or a fluid bed machine used mainly to granulate.
- 84193900 (other, within subheading 841939: dryers; for products n.e.c. in heading no. 8419, not used for domestic purposes) when the machine is a fluid bed dryer whose main job is drying granules or pellets with heated air.
The tariff has no single heading for pharmaceutical machinery, so each machine follows what it does. Tablet presses fall in the residual machinery heading, capsule fillers in the filling machinery heading, mixers and granulators in the mixing machinery subheading, and dryers in the heat treatment heading. A machine that coats tablets has no ruling that settles its line.
In India the GST HSN code and the export ITC-HS code come from the same nomenclature. A GST invoice needs only the first 4 or 6 digits, depending on your turnover; the export shipping bill carries the full 8-digit ITC-HS line. The classification is shown here; the applicable GST rate is not. Official source.
A classification is a fact any lookup can give you. The correct code still does not tell you which countries are buying pharmaceutical machinery right now, what duty each of them charges on the Indian line, or whether that demand is growing or fading. Those answers come from trade data, not from a code table, and they decide whether a market is worth entering. diipl's free Market Research Report answers them for your machine.
The markets that decide your strategy
Your free report shows who buys pharmaceutical machinery from India the most, where demand grows steadily, and where it is emerging, so you target the markets you can actually win.
Who buys from India the most
The markets buying the most from India today.
- Top market
- Top market
- Top market
- Top market
- Top market
Where growth is consistent
Steady, rising demand, not one-off spikes.
- Top market
- Top market
- Top market
- Top market
Where demand is emerging
The fastest-growing import markets.
- Top market
- Top market
- Top market
- Top market
Buying a pharmaceutical machinery in India
- Ask for a GST invoice that lists the machine, its serial number, and the tooling and change parts supplied, so your asset register and spares list match.
- Agree installation and commissioning in writing: levelling, power, dust extraction and compressed air connections, a trial run on your own material, operator training on set-up, tooling change and cleaning, and a signed handover.
- Check your plant plan against the equipment list in Part XIII of Revised Schedule M, and plan separate cubicles with dust control for tablet presses, as the schedule describes, unless the same product runs on every press or the press gives its own enclosed, air-controlled space.
- Ask the maker to support your qualification work with installation and operation protocols, drawings, and material and calibration records.
- Check spares and service: punches and dies, seals, filter bags or cartridges, spray nozzles, and a named engineer with a stated response time.
- Get floor, headroom, utility and lifting details before dispatch, and agree who unloads the machine and moves it into the cubicle or room where it will run.
Buying from Indian pharmaceutical machinery exporters
- Agree Incoterms and who handles unloading and rigging at your site. Press turrets, granulator bowls and coating drums are heavy and precise, so ask how they are crated and braced, and ask that punches and dies travel in separate padded cases.
- Confirm voltage, frequency and number of phases in writing, plus the compressed air and dust extraction connections the machine needs, so the motor, panel and utilities match your plant.
- Ask for the papers your quality team needs for qualification: a match to your specification, design documents, a factory test protocol and report, material records for product-contact parts, and calibration certificates.
- For granulators, dryers and coaters, tell the maker whether powder or solvent vapour is present, and ask for the explosion-protection design and the papers your region asks for.
- Ask for the Certificate of Origin, commercial invoice and packing list in the form your customs broker needs, and confirm the maker's Importer Exporter Code.
- Match the tooling standard of your existing presses so punches and dies interchange, and agree a first-year spares and tooling kit, remote support terms and commissioning engineer visits, because a stopped press holds up a whole batch.
Standards and certifications for pharmaceutical machinery
Pharmaceutical Machinery for each market must meet that market's rules. diipl confirms the certifications your market needs before any meeting. Each requirement below links to its official source.
| Indian standard or rule | What it covers | Official source |
|---|---|---|
| G.S.R. 922(E)Good Manufacturing Practices and Requirements of Premises, Plant and Equipment for Pharmaceutical Products (Schedule M of the Drugs Rules, 1945, as substituted by notification of 28 December 2023) | Written for licensed drug makers, so it shapes what your buyer asks of the machine rather than binding the machine maker. It asks that equipment suit its operation, be easy to clean, and have contact parts that are not reactive, additive or absorptive enough to affect product quality, and that equipment be qualified for design, installation and operation. Part VIII asks for dust control on each tablet compressing machine and filtered air for coating pans and fluid bed dryers. Part XIII lists recommended plant and equipment for tablets and capsules. | View source |
| IS 16504 (Part 1):2019Safety of Machinery: Electrical Equipment of Machines Part 1 General Requirements (First Revision) | A general machine-safety standard for the electrical equipment of machines, identical to IEC 60204-1:2016 and not specific to pharmaceutical machines. Ask the maker whether the control panel and wiring of the press, granulator or coater follow it. | View source |
| Export requirement | Region | What it means | Official source |
|---|---|---|---|
| ATEX check and CE marking for granulating, drying and coating machines | European Union | Granulators, dryers and coaters handle fine powder and sometimes solvent. The European Commission says Directive 2014/34/EU covers equipment and protective systems for potentially explosive atmospheres, where air mixes with gases, vapours, mists or dusts, and that CE marking can only be affixed after testing and the conformity assessment procedure. Ask the maker whether your machine falls under it. | View source |
| EU GMP Annex 15 qualification stages for equipment | European Union | Annex 15 to EudraLex Volume 4 sets the stages a buyer's quality team follows: user requirements, design qualification, factory and site acceptance testing, then installation, operational and performance qualification. Installation checks include materials of construction and instrument calibration. Where protocols come from a third party, the plant's own people confirm they suit its procedures before approval, and vendor protocols may be supplemented. | View source |
| WHO good manufacturing practices for pharmaceutical products: main principles (equipment section) | International reference (WHO guidance) | WHO says this guide shall be used as a standard to justify GMP status when manufacturing authorizations are assessed, and as a basis for inspecting plants. Its equipment clauses match Indian Schedule M: equipment suits its operation, is easy to clean, and has contact parts that are not reactive, additive or absorptive enough to affect product quality. Ask your buyer which national rule or WHO guide the plant follows, then match the machine documents to it. | View source |
For pharmaceutical machinery manufacturers
diipl generates verified buyers for Indian pharmaceutical machinery manufacturers. We research which buyer segments and regions need your machine, run targeted outreach, verify each buyer's need, budget, authority and timeline, and arrange a direct meeting. We never publish your name, phone number or prices.
Start with a free Market Research Report
Tell us the pharmaceutical machinery you make. Our research team maps where your buyers are, then generates verified buyers matched to your capacity.
Pharmaceutical Machinery: frequently asked questions
Who makes pharmaceutical machinery in India?
diipl does not publish manufacturer names. You tell diipl what you need: the machine, batch size, output and dosage form. diipl then matches a maker that has passed GSTIN verification and a capacity audit, confirms its Importer Exporter Code (IEC) and the certificates your market needs, and arranges a direct meeting. For this machinery, the audit includes a trial run of the press, granulator or coater on the factory floor and a check of how product-contact parts are finished and sealed.
What should I specify when buying commercial pharmaceutical machinery?
Start with the dosage form and the batch size you run. For a tablet press, give tablet size, shape, hardness and output per hour. For a granulator, dryer, coater or blender, give working volume, the bulk density of your material and whether solvents are used. Then state dust control, product-contact materials, cleaning method, controls and records, power supply, and the qualification documents you need.
Which standards or certifications apply to pharmaceutical machinery?
The main Indian rule that shapes these machines is Revised Schedule M of the Drugs Rules, notified as G.S.R. 922(E) on 28 December 2023. It applies to licensed drug makers and asks that equipment suit its operation, be easy to clean, have contact parts that are not reactive, additive or absorptive enough to affect quality, and be qualified. Part VIII adds dust control for tablet compression, and Part XIII lists recommended plant and equipment. For electrical and export rules, see the lists on this page.
What is the HSN code for pharmaceutical machinery?
The code for pharmaceutical machinery depends on which machine it is, because tablet presses, capsule fillers, mixers and granulators, and dryers each fall under a different heading, and no official text settles the line for tablet coating pans and drum coaters: 84798970 when the machine presses powder into tablets between punches and dies and the tablets are pharmaceutical goods; 84223000 when the machine fills capsule shells with powder, granules or pellets and closes them; 84798200 when the machine mixes, blends or granulates powders, such as a rapid mixer granulator, a container blender, or a fluid bed machine used mainly to granulate; 84193900 when the machine is a fluid bed dryer whose main job is drying granules or pellets with heated air. The tariff has no single heading for pharmaceutical machinery, so each machine follows what it does. Tablet presses fall in the residual machinery heading, capsule fillers in the filling machinery heading, mixers and granulators in the mixing machinery subheading, and dryers in the heat treatment heading. A machine that coats tablets has no ruling that settles its line. The export shipping bill carries the full 8-digit line and a GST invoice its first 4 or 6 digits, depending on your turnover, so confirm the line for your exact machine before you file. The HS code finder lists every 8-digit line.
Can Indian manufacturers export pharmaceutical machinery?
Yes. Importers run regulated plants, so their quality teams ask for more than a machine: design and test documents, records for product-contact materials, calibration certificates and a factory acceptance test. Granulators and dryers may also need explosion-protection papers for the region. Buyers match voltage and frequency, check that punches and dies fit their tooling standard, and expect spares and remote support. diipl confirms the Importer Exporter Code (IEC) and the certificates before arranging a meeting.
Which industries buy pharmaceutical machinery?
Tablet and capsule plants are the core buyers, including contract manufacturing units and loan licence holders. Nutraceutical and supplement makers also use tablet presses. Makers of active ingredients buy granulating and coating equipment for their physical processing steps. Pilot plants and development units buy smaller machines before scale-up.
I manufacture pharmaceutical machinery. How do I find verified buyers?
diipl studies which buyer segments and regions need your machine, runs outreach to them, and qualifies each buyer on the need, the budget, who signs and when they plan to buy. It then arranges a direct meeting. Your name and contact details are never published. For this machinery, the useful inputs are your output and batch ranges, the dosage forms you serve, your tooling standards, your qualification document pack, and any dust-control or explosion-protection options.
How do I size the output of a rotary tablet press?
Work back from the tablets you must make per shift, then add margin. Rated output rises with the number of stations, turret speed, tooling size and shape, and the material. One maker's high-volume presses list 49 to 79 stations and 58,800 to 758,400 tablets an hour. Ask for output proven on your own granules, not only the top figure.
Should I choose wet or dry granulation for my tablets?
Wet granulation adds a liquid binder to agitated powder, using a high shear granulator or a fluid bed granulator, and the wet mass is then dried. Dry granulation presses powder into slugs or squeezes it between rolls in a roller compactor, which suits moisture or heat sensitive products. Your formulation team makes the choice, so tell the maker which route you use before you finalise the specification.
Does a granulator or fluid bed dryer need explosion protection?
It depends on what you process. A mixture of air with dust or solvent vapour can form a potentially explosive atmosphere, and the European Commission explains that the ATEX Directive 2014/34/EU covers equipment and protective systems made for such atmospheres. Your safety team decides what your product needs. Tell the maker if powder or solvent is present, and ask for the design basis and documents.
Which qualification documents should come with a pharmaceutical machine?
Expect a match to your user requirements, design documents, a factory acceptance test protocol and report, installation and operation qualification protocols, drawings, and records that show materials of construction and instrument calibration. EU Annex 15 describes these stages. It says that, where justified, some factory tests need not be repeated on site if transport and installation do not affect the function. Your quality team approves the final protocols.
More machinery
Related products
Buying or making pharmaceutical machinery?
diipl is a managed buyer-generation service, not a listing site. Buyers share a requirement and meet a verified Indian manufacturer directly; manufacturers get verified buyers without paying for listings or chasing enquiries.
in India
from abroad
this machine